Click here to view our Covid-19 statement

Plenum Access Control Composite Cable - CMP/CL2P, Shielded (18/4 AWG + 22/4 AWG + 22/2 AWG + 22/3 AWG), 500ft and 1000ft

SKU: BCC-109
Vendor
Primus Cable
Regular price
$769.00
Sale price
$769.00
Regular price
$0
Sold out
Unit price
Quantity must be 1 or more
1000ft
500ft

Description

Commercial Applications Plenum CMP Rated

Description

Access Control Cable for Security Alarm System Applications

This composite cable features one 18/4 AWG, one 22/2 AWG, one 22/4 AWG, and one 22/3 AWG shielded conductor. Our access control cables are designed for easy installation, saving time and money during setup, pulling, and termination. BCC-109 Access Control Composite Cable is engineered for seamless installation and meets the rigorous demands of Building Access Control Systems.


Explore our portfolio of high quality Access Control Cables

Plenum - CMP
Riser - CMR
Standard - CM

Access Control Cables - Applications

Our access cables also include print legends to allow for quick identification of each cable application. Time is precious and the convenience of the cables at installation makes our access cables the choice for multiple access control applications.

The Access Control Composite series includes four components required for card readers, door contacts, locking power, and retinal scanners in commercial buildings, distribution centers, manufacturing facilities, government buildings, and educational campuses.


Features

Features

  • 18AWG/4 + 22AWG/3 Pair Shielded + 22AWG/2 + 22AWG/4 Access Control Cable
  • Stranded Copper Conductors
  • Plenum CMP rated PVC jacket for vertical, floor to floor access control wiring
  • For indoor riser applications.
  • Outer Jacket Material: CMP/CL3P PVC
  • Outer Jacket OD = 0.453in. (11.5mm.)
  • Jacket rip cord inside each component for ease of jacket separation
  • Installer friendly with color coded stripes for quick identification.
  • Maximum Operating Voltage: 300 V RMS
  • Storage Temperature Range: -25 - 75°C
  • Installation Temperature Range: -25 - 75°C
  • Operating Temperature Range: 0 - 50°C

Specifications

Specifications

Technical Specs:

Conductor: Stranded Bare Copper
Insulation: LS PVC
Jacket: Yellow CMP/CL3P
Standard Length: 500 Foot & 1000 Foot Reels
Rating: NEC Article 800 Type CMP/CL2P RoHS Compliant
Overall Nominal O.D.: .480
Component # Conductor Size # of Conductors Conductor Colors Nominal O.D. Insulation Thickness Jacket Color
1 18 AWG 4 Cond White, Red,
Black, Green
.183 .008 White/Purple Stripe
2 22 AWG 3 Pairs Shielded Cond Black/Red
White/Green
Brown/Orange
.168 .007 White/Yellow Stripe
3 22 AWG 2 Cond Black, Red .128 .007 White/Green Stripe
4 22 AWG 4 Cond White, Black,
Red, Green
.138 .007 White/Red Stripe

Additional Information

Where to use Plenum Access Control Cable

A broad range of applications exist for access control composite cabling. It is widely used with keypad/card readers, retinal scanners, door contact, request to exit and lock power device connectivity in commercial settings such as schools, universities, hospitals, airports, government buildings, train and transportation centers, stadiums, and arenas. Since this access control cable has multiple conductors under one jacket, the preparation, set up, and termination time is shorter.



Plenum vs Riser in Cabling Design - Why Plenum?

A plenum space is an open area above the drop ceiling or below the floor that is used for air circulation in buildings. This could be a problem if there is ever a fire. Using non-plenum cables in a plenum space can spread fire and toxic smoke throughout a building. Plenum cable uses a flame-retardant jacket that is made of special plastics to prevent the release of harmful smoke. Plenum cable is mostly used in commercial applications such as schools and hospital buildings that house a large population of people. It also is required in most multi-floor business buildings with large plenum space areas.

1. Plenum-Rated Cable: Plenum cables have a higher fire rating and are designed with a fire-retardant plastic jacket of either a low-smoke PVC or a fluorinated ethylene polymer (FEP).

2. Riser-Rated Cable: Riser-rated cables run between floors through cable risers or in elevator shafts in non-plenum areas. These cables must also self-extinguish and prevent the flame from traveling up the cable in a vertical burn test.

3. General Purpose Cable: General Purpose cables have no fire rating. These are not comparable to Riser or Plenum cable jackets because when general-purpose cables burn they release smoke and toxins, as there are no fire safety aspects to these cables.





Primus Cable offers a complete line of communications and control cables. Shop high-quality communications and control cables.

What's in the Box

What's in the Box

  • Quantity: 500 Foot & 1000 Foot Reel
  • Cable is supplied on a wooden spool.
  • Access Control Cable - CMP/CL2P, (18/4 AWG Conductors + 22/4 AWG Conductors + 22/2 AWG Conductors + 22/3 AWG Pair Shielded Conductors)


Description

Access Control Cable for Security Alarm System Applications

This composite cable features one 18/4 AWG, one 22/2 AWG, one 22/4 AWG, and one 22/3 AWG shielded conductor. Our access control cables are designed for easy installation, saving time and money during setup, pulling, and termination. BCC-109 Access Control Composite Cable is engineered for seamless installation and meets the rigorous demands of Building Access Control Systems.


Explore our portfolio of high quality Access Control Cables

Plenum - CMP
Riser - CMR
Standard - CM

Access Control Cables - Applications

Our access cables also include print legends to allow for quick identification of each cable application. Time is precious and the convenience of the cables at installation makes our access cables the choice for multiple access control applications.

The Access Control Composite series includes four components required for card readers, door contacts, locking power, and retinal scanners in commercial buildings, distribution centers, manufacturing facilities, government buildings, and educational campuses.


Features

Features

  • 18AWG/4 + 22AWG/3 Pair Shielded + 22AWG/2 + 22AWG/4 Access Control Cable
  • Stranded Copper Conductors
  • Plenum CMP rated PVC jacket for vertical, floor to floor access control wiring
  • For indoor riser applications.
  • Outer Jacket Material: CMP/CL3P PVC
  • Outer Jacket OD = 0.453in. (11.5mm.)
  • Jacket rip cord inside each component for ease of jacket separation
  • Installer friendly with color coded stripes for quick identification.
  • Maximum Operating Voltage: 300 V RMS
  • Storage Temperature Range: -25 - 75°C
  • Installation Temperature Range: -25 - 75°C
  • Operating Temperature Range: 0 - 50°C

Specifications

Specifications

Technical Specs:

Additional Information

Where to use Plenum Access Control Cable

A broad range of applications exist for access control composite cabling. It is widely used with keypad/card readers, retinal scanners, door contact, request to exit and lock power device connectivity in commercial settings such as schools, universities, hospitals, airports, government buildings, train and transportation centers, stadiums, and arenas. Since this access control cable has multiple conductors under one jacket, the preparation, set up, and termination time is shorter.



Plenum vs Riser in Cabling Design - Why Plenum?

A plenum space is an open area above the drop ceiling or below the floor that is used for air circulation in buildings. This could be a problem if there is ever a fire. Using non-plenum cables in a plenum space can spread fire and toxic smoke throughout a building. Plenum cable uses a flame-retardant jacket that is made of special plastics to prevent the release of harmful smoke. Plenum cable is mostly used in commercial applications such as schools and hospital buildings that house a large population of people. It also is required in most multi-floor business buildings with large plenum space areas.

1. Plenum-Rated Cable: Plenum cables have a higher fire rating and are designed with a fire-retardant plastic jacket of either a low-smoke PVC or a fluorinated ethylene polymer (FEP).

2. Riser-Rated Cable: Riser-rated cables run between floors through cable risers or in elevator shafts in non-plenum areas. These cables must also self-extinguish and prevent the flame from traveling up the cable in a vertical burn test.

3. General Purpose Cable: General Purpose cables have no fire rating. These are not comparable to Riser or Plenum cable jackets because when general-purpose cables burn they release smoke and toxins, as there are no fire safety aspects to these cables.





Primus Cable offers a complete line of communications and control cables. Shop high-quality communications and control cables.

What's in the Box

What's in the Box

  • Quantity: 500 Foot & 1000 Foot Reel
  • Cable is supplied on a wooden spool.
  • Access Control Cable - CMP/CL2P, (18/4 AWG Conductors + 22/4 AWG Conductors + 22/2 AWG Conductors + 22/3 AWG Pair Shielded Conductors)