Descriptions
Smart Tracker Rack Mount NEMA Rated PDU
The Smart Tracker is an IP-ready, GPS-enabled device that provides the system owning and/or managing agency with remote access control of (8) NEMA Rated 5-15R outlets, (8) 10A output relays, (8) digital inputs, (2) analog DC voltage inputs (for battery voltage monitoring), plus temperature and humidity sensors – all in one unit!
Embedded in each Smart Tracker is a web page that provides a summary of system details and operating states. The web page allows the user to configure all outlets, relays, inputs, and other system parameters. This control is available anywhere with access to a standard web browser – saving time and money! While it is ideal in the field, the Smart Tracker has also proven valuable in other settings such as test laboratories, traffic control centers, server rooms, equipment hubs, and remote locations.
The three basic functions of the Smart Tracker are control, respond and automate.
Control - Outlets and Relays
While working against nature, power products face freezing temperatures, heat, and humidity. If high or low temperature and/or humidity thresholds are exceeded in the field, the agency will be notified automatically through an email or an SNMP trap of the event. The user may then enable power through outlets and/or relays to auxiliary fan kits or battery heater mats in order to maintain the functionality and efficiency of their cabinet.
Respond - Unpredictable & External Events
Utilizing the Smart Tracker, the user can effectively respond to unexpected events that occur on the power line. In the event of a brownout, the Smart Tracker will remotely indicate that the timer relay on the power supply has been exceeded and that the intersection may now be in flash mode. Once this occurs, the runtime is limited and a technician should report to the site to apply a generator to the system before power to the device is lost.
Automate – Tasks
A cabinet’s network switch, modem, or radio communication device may be plugged into outlet one and renamed “Communication Device”. Once the Smart Tracker has been set up for the cabinet’s network switch and is configured to be reset by pinging, an automated feature. It will then reset an outlet when network communication is lost. Ping can automatically restore network communication to the Smart Tracker if a network switch or network device has become unresponsive. A simple power reset may resolve the issue
Features
Features
- Remotely command AC/DC power devices to cycle on or off
- Alarm notifications alert traffic controllers
- Control your equipment with the advanced scheduling feature
- Digital inputs indicate when external events have occurred,
- Fits standard 1RU 19"
Specifications
Specifications
HARDWARE SPECIFICATIONS | ||
---|---|---|
Remote Updates | Firmware and Unit Configuration | |
No. Outlets | 8 Individually Controlled Outlets | |
LCD | Dual Line 2x20 Backlit | |
System Clock | NEMA 5-15R, 15A/125 VAC, 60Hz | |
Embedded Webpage | Password Protected User Interface | |
User Input | Pushbutton for Specific Actions | |
Event Log | Stores Thousands of Events | |
Automation | Scheduled Events and Actions | |
LEDs | Indicators for Active Outlets, Relays, and Digital Inputs | |
Relay & Input Connections | Screw Terminal Plugs for 12-22AWG Wire | |
Dimensions | 1.7”H x 7.0”D x 19”W (43mm x 482mm x 178mm) | |
Weight | 5lbs (2.26Kg) | |
Color | Black/Blue | |
Mounting | 1RU Rack Mounting w/ Adjustable Rack Mount Brackets or Shelf Mount |
DIGITAL INPUT SPECIFICATION | ||
---|---|---|
No. Digital Inputs | 8 Individual Inputs (2 Contacts per Input) | |
Temperature Sensor | Embedded | |
Digital Input Voltage | 5VDC, 10mA Max., Opto-Isolated Inputs | |
Humidity Sensor | Embedded | |
Analog Voltage(DC) Input | 2 Independent DC Measurement Inputs | |
Analog Input Voltage (DC) | 0-60VDC |
OUTPUT RELAY SPECIFICATIONS | ||
---|---|---|
No. Output Relays | 8 Individual Out Relays | |
Relay Switching Voltage | 250VAC, 125VDC MAX | |
Relay Current Capacity | 10 Amps, Each |
AC INPUT SPECIFICATIONS | ||
---|---|---|
Voltage Range | 85-154VAC;120VAC Nominal | |
Power Cord | Pluggable 5-15P, C13 15A/125VAC | |
Frequency | 60Hz ±3Hz | |
Circuit Breaker Rating | 15A | |
Current Capacity | 15A |
ENVIRONMENTAL SPECIFICATION | ||
---|---|---|
Operating Temperature | -37°C to +74°C (-34°F to 165°F) | |
Operating Humidity | 5-95% Non-condensing | |
Storage Temperature | -45°C to 85°C (-49°F to 185°F) |
COMMUNICATION SPECIFICATIONS | ||
---|---|---|
Network Interface | 10/100/1000 BASE-T Ethernet Port, RJ45 Connection, Auto MDI-x | |
Network Protocols | NTCIP/TCP/IP/HTTP/SNMP/SNTP/UDP | |
IP Addressing | DCHP and Static IP Addressing | |
Notification Type | SNMP Traps/Email Notification |
SAFETY STANDARD SPECIFICATIONS | ||
---|---|---|
Standards | NEMA TS2-2016 v03.07 |