RDUP (RUS) PE-89 AL - 25 Pair, 22 AWG Filled Foam Skin Cable 5000ft Black
Core Construction
Core Construction |
|
Conductors: | Solid, annealed copper; sizes 22 AWG |
Insulation: | Dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color coded in accordance with telephone industry standards. |
Twisted Pairs: | Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk. |
Core Assembly: |
25 pairs and less: pairs are assembled together in a single group. More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder. |
Filling Compound: | The entire core assembly in completely filled with ETPR compound, filling the interstices between the pairs and under the core tape. |
Core Wrap: | Non-hygroscopic dielectric tape applied longitudinally with an overlap. |
Sheath
Sheath |
|
Aluminum Shield: |
Corrugated, copolymer-coated, 0.008" aluminum tape applied longitudinally with an overlap. The sheath interfaces are flooded with an adhesive water-blocking compound. |
Jacket: | Black, linear low density polethylene |
Additional Information
Application(s) |
Intended for duct and direct buried installations where protection against water and mositureentry is required and may also be installed aerially. |
Compliance |
Rural Development Utility Program (RDUP) 7CFR 1755.890 (RUS PE-89) RoHS Compliant (effective 1/1/10) |
Packaging
Packaging |
Standard lengths are shipped on non-returnable wood reels. Non-standard packaging is available upon request. |
Coming Soon...
Nomial Cable Data |
|
Pairs: | 25 |
Size: | 22 AWG. |
O.D. (Inches): | 0.62 |
Weight (Lbs./MFT): | 205 |
Standard Length (Feet): | 5000 Feet |
Core Construction |
|
Conductors: | Solid, annealed copper; sizes 19, 221 and 24 AWG |
Insulation: | Dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color coded in accordance with telephone industry standards. |
Twisted Pairs: | Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk. |
Core Assembly: |
25 pairs and less: pairs are assembled together in a single group. More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder. |
Filling Compound: | The entire core assembly in completely filled with ETPR compound, filling the interstices between the pairs and under the core tape. |
Core Wrap: | Non-hygroscopic dielectric tape applied longitudinally with an overlap. |
Sheath |
|
Aluminum Shield: |
Corrugated, copolymer-coated, 0.008" aluminum tape applied longitudinally with an overlap. The sheath interfaces are flooded with an adhesive water-blocking compound. |
Jacket: | Black, linear low density polethylene |
Application(s) |
Intended for duct and direct buried installations where protection against water and mositureentry is required and may also be installed aerially. |
Compliance |
Rural Development Utility Program (RDUP) 7CFR 1755.890 (RUS PE-89) RoHS Compliant (effective 1/1/10) |
Packaging |